MODEL
A
ANALOGUE INSULATION TESTER
INSTRUCTION MANUAL
KYORITSU ELECTRICAL INSTRUMENTS
WORKS,LTD., TOKYO JAPAN
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - ANALOGUE INSULATION TESTER

MODEL3131AANALOGUE INSULATION TESTERINSTRUCTION MANUALKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD., TOKYO JAPAN

Página 2 - Contents

―8―5-2 Mechanical Zero AdjustmentCheck that the pointer lines up with the middle of the mark on the scalecorrectly. If not, adjust it by rotating the

Página 3 - 1. Safety Precautions

―9―6. Operation 6-1 Disconnection and check of power source of circuit under testDANGER● To avoid possible electrical shock, do not perform measuremen

Página 4

―10―6-2 Insulation Resistance MeasurementDANGER● Always test the circuit or equipment to ensure it is surely de-energizedbefore measurement a

Página 5 - 2. Features

―11―DANGERDo not touch the circuit under test immediately after testing. Capacitancestored in the circuit may cause electric shock.Leave the

Página 6 - 3. Specifications

―12―Principle of Continuity Testing (Resistance Test)Resistance value can be obtained by applying a certain current to theresistance under test an

Página 7

―13―7. Back Light Function To facilitate working at night or dimly lit situations, a back light function isprovided which illuminates the d

Página 8 - 4. Instrument Layout

―14―8. Battery & Fuse Replacement 8-1 Battery Replacement① Disconnect the test probe from the instrument.② Open the battery compartment cover by

Página 9 - 5. Preparation for Testing

―15―9. Notes on Accessories 9-1 How to Fit Strap Belt and Test Probe PouchBy hanging the instrument around the neck, both hands can be usedfre

Página 10

―16―10. Cleaning of the Instrument ◎ Cleaning the meter coverThis instrument is managed by our company's quality standard and isdelivered in the

Página 11 - 6. Operation

―17―MEMO

Página 12

Contents 1. Safety Precautions ... 12. Features ...

Página 13

01-1292-1487ADISTRIBUTORKYORITSU ELECTRICALINSTRUMENTSWORKS, LTD.No.5-20, Nakane 2―chome, Meguro-ku,Tokyo, 152-0031 JapanPhone:(03)3723―0131Fax:(03)37

Página 14

―1―1. Safety Precautions○ The instrument is designed and tested in accordance with the followingstandards and supplied in the best condition.・IE

Página 15 - 7. Back Light Function

―2―DANGER● Do not use this instrument on energized (LIVE) circuits.● Do not make measurement in the presence of flammable gasses.Otherwise, the use o

Página 16 - SPARE FUSE

―3―2. FeaturesMODEL-3131A is an analogue insulation tester with five ranges for insulationresistance measurement and continuity testing (resistanc

Página 17 - 9. Notes on Accessories

―4―3. Specifications●Measuring Range and Accuracy(at 23±5°C, relative humidity 45-75%)Insulation Resistance Ranges:(IEC 61557-2)Nominal Output Voltage

Página 18 - 11. Service

―5―Typical Number of Measurements(central tendency for supply voltage up to6.5V)Insulation Resistance Ranges:1000V/400MΩ Range Approx. 500 times min.5

Página 19

―6―4. Instrument Layout ①METER MOVEMENT ZERO ADJUST ②TEST BUTTON③SCALE PLATE ④LIVE CIRCUIT WARNING LED⑤POWER-ON INDICATION LED ⑥CONTINUITY ZERO ADJUST

Página 20 - INSTRUMENTS

―7―5. Preparation for Testing 5-1 Removing the CoverModel 3131A has a dedicated cover to protect against an impact fromthe outside and prevent the op