Kyoritsu 2413F Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Ferramentas Kyoritsu 2413F. KYORITSU 2413F User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
KEW SNAP
Series
KEW SNAP 2413F
DIGITAL CLAMP METER
KYORITSU ELECTRICAL INSTRUMENTS
WORKS,LTD.
INSTRUCTION MANUAL
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1 - KEW SNAP

KEW SNAPSeriesKEW SNAP 2413FDIGITAL CLAMP METERKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD.INSTRUCTION MANUAL

Página 2 - Contents

―8―Power Source :One 6 F22 or equivalent batteryLow Battery Warning :“B”symbol is shown on the display.Current Consumption :Approx. 5mA max.Standard(S

Página 3 - 1.Safety Warnings

―9―4.Instrument Layout⑩ Fig.2

Página 4

―10―① LCDField effect liquid crystal display with maximum indication of 1999.Function symbol(mA, A) and decimal point automatically appear asthe funct

Página 5 - CAT.III

―11―5.Operation5−1 Preparation(1) To Check battery set the function/range switch (5) To the desiredposition. If the display is clear without symbol “B

Página 6 - 2.Features

―12―CAUTION●Transformers jaws , especially their tips, have been preciselyadjusted to obtain maximum accuracy. Take sufficient care toavoid shock, vib

Página 7 - 3.Specifications

―13―Note:When measuring large current, observe the time limit specified insection 3, Specifications. Otherwise, the transformers jaws mayoverheat, res

Página 8 - ●AC Output

―14―5−3 How to Use Peak Hold Function10ms or 100ms response time can be selected for peak holdmeasurement. Make selection according to your applicatio

Página 9

―15―Note 2:If it is necessary to read the display away from the conductorin a peak hold measurement, press the data hold switch (2)first and then remo

Página 10

―16―5−4 How to Use The Frequency Selector SwitchKEW SNAP 2413F has a very good frequency response because of theelectromagnetic property of its transf

Página 11 - 4.Instrument Layout

―17―5−5 How to Use Data Hold FunctionPush in the Data Hold button to freeze the reading. This is especiallyuseful for taking a reading in a dimly lit

Página 12

Contents1.Safety Warnings ………………………………………………………12.Features ………………………………………………………………43.Specifications …………………………………………………………54.Instrument Layout

Página 13 - 5.Operation

―18―KEW SNAP 2413F

Página 14

Replace the battery when B symbol appears on the LCD display.(1) Set the function/range switch to the OFF position.(2) Unscrew and remove the battery

Página 15

―20―Use a damp cloth detergent for cleaning the body of the instrument. Toavoid possible deforming or discoloring, do not use solutions containingsolv

Página 16

―21―Use the following troubleshooting guide for hints on problems withinstrument operation.8.Before Sending for RepairTransformer jaws buzzwhen measur

Página 17

04―10DISTRIBUTOR92―1433AKyoritsu reserves the rights to change specifications ordesigns described in this manual without notice and withoutobligations

Página 18

―1―1.Safety WarningsMake sure to read through this instruction manual before using thisinstrument.●The instrument has been designed, manufactured, and

Página 19

Following symbols are used on the instrument and in the instructionmanual. Attention should be paid to each symbol to ensure your safety. Refer to the

Página 20 - KEW SNAP 2413F

―3―CAUTION●Make sure that the function selector switch is set to anappropriate position before making measurement.●Be sure to set the function selecto

Página 21 - 6.Battery Replacement

―4―KEW SNAP 2413F is a unique digital clamp meter for both very lowcurrent and high current measurements. Its shielded transformers jawsminimizes the

Página 22 - 7.Cleaning

―5―Measuring Ranges and Accuracy●AC Current 3.Specifications※Refer to Figure 1 for frequency characteristics.●Effect of External Stray Magnetic Field1

Página 23 - 8.Before Sending for Repair

―6―Range200mA2A20A200A1000AMeasuring Range0∼200mA0∼2A0∼20A0∼200A0∼500A501A∼1000AAC Output VoltageAccuracy0∼200mV±2%rdg±2.5%rdg±3%rdg±5%rdg0∼50mV50∼100

Página 24 - DISTRIBUTOR

―7―●DC Output*DC voltage is output in proportion to the display reading, whichreflects frequency selector or peak hold switch position−200mVDC for 200

Comentários a estes Manuais

Sem comentários