INSTRUCTION MANUAL
Digital Earth Resistance Tester
MODEL 4105A
KYORITSU ELECTRICAL INSTRUMENTS
WORKS, LTD.
01-07 92-1494
KYORITSU ELECTRICAL
INSTRUMENTS
WORKS, LTD.
No.5-20,Nakane 2-chome, Meguro-ku, Tokyo
152-0031 Japan
Phone :(03) 3723-0131 Fax : (03) 3723-0152
URL : http://www.kew-ltd.co.jp
Factories : Uwajima & Ehime
Kyoritsu reserves the rights to change specifications or designs described in
this manual without notice and without obligations.
DISTRIBUTOR
Vista de página 0
1 2 3 4 5 6 7 8 9 10

Resumo do Conteúdo

Página 1 - MODEL 4105A

INSTRUCTION MANUALDigital Earth Resistance TesterMODEL 4105AKYORITSU ELECTRICAL INSTRUMENTSWORKS, LTD.01-07 92-1494KYORITSU ELECTRICAL INSTRUMENTSWO

Página 2 - CONTENTS

---- 17 ----9. Before Sending for ServiceIf this instrument should fail to operate correctly, return it to your nearestdistributor stating the exact n

Página 3 - ---- 3 -------- 2

1. Safty PrecautionsThe instrument is designed, manufactured, tested and shipped in primecondition in accordance with the following standards.IEC 6101

Página 4 - 2. Features

DANGER is reserved for conditions and actions that are likely to causeserious or fatal injury.WARNING is reserved for conditions and actions that can

Página 5 - ---- 7

3. SpecificationsMeasuring Range and Accuracy (at 23 5°C and RH 75% or less)RangeMeasuring RangeAccuracyEarth Voltage 0 - 199.9V 1.0% rdg 4 dgt20Ω 0

Página 6 - 6.Operating Instructions

Power Source9V DC : R6P (SUM-3) x6Overload ProtectionEarth resistance ranges : 280V AC/DC (10 seconds)Earth voltage range : 300V AC/DC (1 minute)Insul

Página 7 - ---- 11

4. Layout Diagramq LCD Display w Battery Replacement Marke Indication LED With qq(Low Battery Symbol)qqMeasurement(Green) r Press To Test Buttont Ra

Página 8 - ---- 12

---- 10 ----20Ω when the earth resistance is low. This indicated value is the earthresistance of the earthed equipment under test.Note : If the auxi

Página 9 - 7. Battery Replacement

wEarth Voltage MeasurementSet the range switch to EARTH VOLTAGE position in the condition ofq. Earth voltage will be indicated on the display. Make su

Página 10 - 10. Service

---- 15 ----7. Battery ReplacementDANGERNever attempt to open the battery compartment cover, if the outersurface of the instrument is wet.Never attemp