Kyoritsu 5000 Instruction Manual Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Ferramentas Kyoritsu 5000 Instruction Manual. KYORITSU 5000 Instruction Manual User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
MODEL 5000/5001
KEW LEAK LOGGER
Leak Logger for Measuring & Recording leakage current
INSTRUCTION MANUAL
KYORITSU ELECTRICAL INSTRUMENTS
WORKS,LTD.
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - MODEL 5000/5001

MODEL 5000/5001KEW LEAK LOGGERLeak Logger for Measuring & Recording leakage currentINSTRUCTION MANUALKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD.

Página 2 - Contents

―8―3-4)Displayed messageMessageMeaningSensor is not connected.Over-rangeMenu: Setting1(SET.1)View or change the recording mode/ condition.Menu: Settin

Página 3 - 1. Safety Warnings

―9―4.Recording proceduresFollowing explains the flow of operation: through preparation to the stopof recording.P. 10Select the appropriate sensor, an

Página 4

―10―Step1: Preparation1. Connect the clamp sensor to theinstrument firmly with careful attention tothe orientation of the connector.2. Press the

Página 5 - 2. Features

―11―Step2: Confirmation and change of set valueConfirm the mark indicating theselected recording mode.Refer to "5. Recording modes andconditi

Página 6 - 3.Instrument layout

―12―1. Clamp on the measured object and fixthe Clamp sensor.2. Instrument shall be firmly fixed so as notto come off easily.1)Hang the instrument o

Página 7 - 3-2) Menu configuration

―13―4. Press the button to switch themeasurement ranges at each channel. The Range hold function is activatedwhen the mark is displayed on theLCD.Not

Página 8

―14―Step4: Start of recordingFollow the procedures stated below and start recording. Be sure to check each setting before starting a recording since

Página 9 - 3-1) LCD

―15―Following operations are available during a recording.* Display the measured value at each channel button* Recording state: Display the max. recor

Página 10 - 3-4)Displayed message

―16―5. Recording modes and conditionsContinuous recording mode: Recording interval of 1min.Max. number of recorded dataUsing all 3 channels Using 2 ch

Página 11 - 4.Recording procedures

―17―2. Press the button when "SEt.1" isdisplayed on the LCD.3. The selected recording mode is displayed.When (Continuous recording mode)i

Página 12

Contents1. Safety warnings ... 12. Features ...

Página 13

―18―5. State of One-time system is displayed.on: Recording stops when memory becomesfull.off: Overwrite the old data, and store thelatest data.¡Press

Página 14

―19―Event recording mode: Current set value of 15mAMax. number of recorded dataSetting procedureUsing all 3 channels Using 2 channels Using only 1 cha

Página 15

―20―4. Pre-set current value at channel 1 isdisplayed. Can be set at every 1mA from 0 to 1000mA¡Press the button and proceed to thenext step wh

Página 16

―21―Max. value recording mode: Current set value of 15mAMax. number of recorded dataUsing all 3 channels Using 2 channels Using only 1 channel330 data

Página 17

―22―4. Pre-set current value on channel 1 isdisplayed. Can be set at every 1mA from 0 to1000mA.¡Press the button and proceed to thenext step

Página 18

―23―Capture recording mode: Current set value of 15mAMax. number of recorded dataSetting procedureUsing only 1 channel345 data1. Power on the instrume

Página 19

―24―4. Pre-set current value on channel 1 isdisplayed.Can be set at every 1mA from 0 to 1000mA.¡Press the button and proceed to thenext step

Página 20

―25―6. Recording modesList of recording modesRecordingmodeDetailsTo check:P.26Condition,IntermittentleakageP.27Occurrence ofleakageP.28Intermittentlea

Página 21

―26―(1) Continuous recording mode¡Sampling period and RMS calculationThe input signal obtained via the connected sensor is sampled (at50Hz,

Página 22

―27―(2) Event recording mode¡Current detection and RMS calculation Sampling is performed consistently at 1.6ms intervals. Current isdetected by

Página 23

―1―1. Safety WarningsThis instrument has been designed, manufactured and tested accordingto IEC 61010: Safety requirements for Electronic Measuring ap

Página 24

―28―(3) Max. value recording mode¡Current detection and RMS calculation Sampling is performed consistently at 1.6ms intervals. Current isdetected

Página 25

―29―(4) Capture recording mode¡Current detection and RMS calculation Sampling is performed consistently only at Channel 1 at 1.6msintervals. Current

Página 26

―30―7. Other settings (Setting2)Menu Setting 2: "SEt.2" Setting items1) Location informationSet the location no. to identify the measuring a

Página 27 - 6. Recording modes

―31―2. Press the button when "SEt.1" isdisplayed on the LCD.3. Press the button when "SEt.2" isdisplayed on the LCD.4. "Loc

Página 28

―32―5. "Auto-power-off":State of Auto-power-off function is displayed.O n : Enables Auto-power-off function.OFF : Disables Auto-power-off f

Página 29 - (2) Event recording mode

―33―7. "Timer": State of Timer function is displayed.Can be set within "00:00" to "23:59".¡Press the button and procee

Página 30

―34―9. Scale value at Channel 2 is displayed.¡Press the button and proceed to thenext step (Scale value at Channel 3) whennot changing the setting¡To

Página 31 - (4) Capture recording mode

―35―8. Data transfer to PC¡IInstall PC software "KEW LOG Soft" on your PC before usingthe instrument. Please refer to the instruction

Página 32 - 7. Other settings (Setting2)

―36―8-2 Preparation for data transmission(1) Power on the instrument, and get the instrument ready for ameasurement.(Note: Data cannot be transferred

Página 33

―37―9. Battery replacementWARNING¡In order to avoid electrical shock, remove sensors from theinstrument when replacing batteries.CAUTION¡Do not mix ne

Página 34

DANGER¡ Never make measurement on the circuit in which voltage overAC300V exists.¡ Do not attempt to make measurement in the presence of flammablega

Página 35

―38―10. Specification¡Measuring Ranges and Accuracy* Continuous recording mode [RMS] (50/60Hz,Sine wave)Crest Factor ≦ 2.5 : Sine wave accuracy +2%+5d

Página 36

―39―¡Display : Liquid crystal display¡Low battery warning : Battery mark display(in 4 levels)¡Overrange indication : "OL" mark appears when

Página 38

―41―MEMO

Página 39 - 9. Battery replacement

04-06 92-1599BDISTRIBUTORKYORITSU ELECTRICALINSTRUMENTSWORKS, LTD.No.5-20, Nakane 2―chome, Meguro-ku,Tokyo, 152-0031 JapanPhone:81―3―3723―0131Fax:81―3

Página 40 - 10. Specification

―3―2. Features¡ This instrument is a leak logger for measuring and recordingleakage current.¡ Capable of recording leakage current from 1 to 3ch wi

Página 41

―4―3.Instrument layout3-1) Panel¡ Operation of button¡ LCD ・・・ P. 7¡ LED current indicator ・・・ P.18¡ USB ・・・ P.35ButtonAt recording / measurement mode

Página 42

―5―3-2) Menu configuration

Página 43

―6―

Página 44 - WORKS, LTD.

―7―3-1) LCD100mA1000mAMark DetailsSelected channel number(The measured value at this channel is displayed.)Auto-power-off is disabled.(Instrument won&

Comentários a estes Manuais

Sem comentários